差出人: Regis Houllier
送信日時: 2008年6月5日木曜日 23:27
宛先: Toru Ishikuma
件名: RMG meeting minute notes

添付ファイル: RMG PGC6000 brochure.pdf; RMG PGC6000 brochure network.pdf

Hello Toru,

Here is below minute notes about our yesterday meeting with RMG:

 

Attendees: Mr Koerte, Mr Zajc, Mr Grexa, Mr Schlegel, Mr Ishikuma & Mr Houllier

04/06/08 at Butzbach

 

Discussion which were supposed to be on Sales activity and business forecast has been quickly stopped by Mr Koerte.

Mr Koerte has informed Yamatake that they have top priority concern about technical issues that must be solved as soon as possible.

3 main issues:

-          When FF cable is physically disconnected, the SLD100 continues to deliver information via TCP/IP port as everything was OK. The TCP/IP port is still open and data given via this port sounds correct. So there is no way to detect such failure.

-          When connecting HFA100 in parallel of SLD100 and HGC303 FF network, the communication comes instable

-          RMG are not in position to get PTB approval for multi-stream application because they cannot control HGC sequence.

 

RMG wanted to test HGC communication with HDM to see if there is difference with HGC and SLD100. Their HDM did not work. Ishikuma san brings a new one, so they can continue their tests.

 

Mr Ishikuma has indicated several possible solution to fix the non stability with HGC/SLD/HFA:

-          Check LAS (link active Scheduler). Only one should be active

-          Check terminator: two must be installed, no more.

-          RMG will check but they said it should be OK

-           

However RMG has noticed that voltage between the 2 wires of FF cable is only 0Vdc. They ask us if this is normal. Their understanding is that it should be at least+8V to 30Vdc.

 

We agree on having shortly a meeting at Butzbach with our specialist for FF networking and HGC time control. Mr Ishikuma will check possibility with Japan.

 

RMG has started to promote new attached PGC6000 since January 2008. They have already booked 2 orders but cannot deliver due to above technical issues

 

Best regards,

Regis

 

 

YAMATAKE Europe

Regis Houllier

Industrial Division Director

Bosdellestraat 120/2

B-1933 zaventem (Sterrebeek)

Belgium

 

Tel. :    + (33) (0) 3 22 54 83 47

Fax. :    + (33) (0) 3 22 54 83 29

GSM :    + (33) (0) 6 89 59 13 19

E-mail :    rhoullier@yamatake-europe.com

Web :     http://www.yamatake-europe.com